Lazarev Laboratories

SERVICES

Short Circuit Withstand Capability Verification

Windings

Central to power transformer short circuit withstand capability is performance of its windings. Decades of research by Dr. Viktor Lazariev, a co-founder of the company, resulted in the original theory that allows to predict the processes of deformations development in transformer windings under short circuit. The calculation methods, verification criteria and norms based on this theory were implemented in WELDINST software suite. This suite is used at Lazarev Laboratories OÜ for verification of short circuit withstand capability of power transformer windings.

Windings Pressing Structure and Pressing Rings

One of the factors of growing importance in modern power transformers is strength of the winding pressing structure that must sustain the short circuit loads exerted upon it from windings. Similarly, strength of the pressing rings must be verified under winding clamping and under short circuit.

At Lazarev Laboratories OÜ, a three-dimensional FEM calculation is used to verify strength of these components.

Transformer Tank Strength Analysis

Calculations are performed for a variety of loads and operating conditions, including:

  1. Vacuum testing;
  2. Hydrostatic oil pressure;
  3. Transportation on Schnabel car;
  4. Transportation on platform railcar;
  5. Tank lifting;
  6. Tank jacking;
  7. Seismic loads.

User Support

Consulting services are provided to current users of WELDINST (as well al ELDINST by JSC "VIT"). The coverage is as follows:

  1. user re-training;
  2. user support regarding software operation.

VALIDATION

We stay in touch with the transformer manufacturers that integrated our calculation methods and software into their workflow. The table below lists transformers that were designed with application of WELDINST calculation methods and underwent short circuit tests. All the listed designs passed the tests on the first go.

Read more on WELDINST verification criteria in this PDF (11 pages)

Read more on WELDINST experimental validation in this PDF (14 pages)

Transformer Country of origin Date of calculation or test Country where tests were performed
154kV.GIT, gas filled, 20 MVA, 2 limbs, 1-phase South Korea 1998-05-26 South Korea
70MVA, 220kV, 3-phase India 2002-04-17 India
154kV.GIT, gas filled, 20 MVA, 1 limb, 1-phase South Korea 2002-09-03 South Korea
25/31.5MVA, 132/32kV, 3-phase India 2003-08-15 India
SFFZ10—31500/110 (autotransformer), 3-phase PRC 2004-02-20 PRC
SFZ—50000/110, 3-phase PRC 2004-02-20 PRC
TRMGT—1000/10, 3-phase Ukraine 2005-05-16 Ukraine
26 MVA, 132/11.5kV, 3-phase Iran 2005-09-26 Netherlands
40/50MVA, 132/66kV, 3-phase India 2007-09-25 India
25MVA, 132/33kV, 3-phase India   India
35MVA, 220kV, 3-phase India 2008-04-03 India
50MVA, 132/33kV, 3-phase India   India
102MVA, 400/16kV, 1-phase India 2007-06-09 Netherlands
25MVA, 420/11kV, 1-phase India 2009-01-15 India
32MVA, 220/11kV, 1-phase India 2009-01-15 India
17.5MVA, 132/11kV, 1-phase India 2008-10-20 India
315MVA, 400/220/33kV, 3-phase India 2007-08-22 Netherlands
80MVA, 400/11.5kV, 3-phase India 2009-07-20 India
200MVA, 420/21kV, 1-phase India 2009-09-03 Netherlands
45MVA, 21/11.5kV, 3-phase India 2009-09-21 India
82MVA, 15/420/sqrt(3) kV, 1-phase India 2009-04-13 Netherlands
200 MVA, 400/132 kV, autotransformer, 3-phase India 2010 Netherlands
250 MVA, 420/sqrt(3)/20 kV, 1-phase UK — France 2009 — 2010 Netherlands
315MVA, 400/220/33kV, autotransformer, 3-phase India 2010-01-15 Netherlands
40MVA, 230/121/10.5kV, autotransformer, 1-phase India 2008-09-15 India
105 MVA, 400/220/33 kV, autotransformer, 1-phase India 2011-09-24 Netherlands
15 MVA, 66/11kV, 3-phase India 2012-10-05 India
TRDN-40000/110, 3-phase Russian Federation 2012-04 Czechia
27MVA, 132/27 kV traction-feeding transformer, 1-phase India 2013-07 India
50 MVA, 132/33kV, 3-phase India 2014-05 India
5MVA, 66/11.55kV, 3-phase India 2014-08 India
315MVA, 400/220/33kV, autotransformer, 3-phase India 2014-07 Netherlands
130 MVA, 500/150/31.5 kV, autotransformer, 1-phase South Korea 2014 Netherlands
TRDN-40000/110, 3-phase Russian Federation 2015-02 Russian Federation
40 MVA, 60/31.5 kV, 3-phase India 2016 — 2017
(3 units)
Netherlands
40 MVA, 60/10.5 kV, 3-phase India 2016 Netherlands
200 MVA, 242/13.8 kV, 3-phase Taiwan 2017 Netherlands
40 MVA, 60/31.5 kV, 3-phase India 2017 India
40 MVA, 110kV, 3-phase Poland 2018-04-19 Czechia
TDTN-40000/220, 3-phase Russian Federation 2019-10 Russian Federation